top of page

Audio specifications LYRA Music for Tales®

1.0 BNC Audio Masters prerequisites for Mix Facilities
1.1 Audio Master LR - Original Version and Alternate Version
1.2 Audio Stems LR - Original Version

 

2.0 Audio Mix, Stems and Archive
 

3.0 Best Practices

1.0 Audio Masters prerequisites for Mix Facilities

  • Average loudness must be -21 LKFS +/- 5 LU measured on stereo track. Peaks must not exceed -6 db True Peak. Audio should be measured over full program according to ITU-R BS.1770-1 guidelines.

  • Standard .wav or .bwav files are required in multiple mono (not interleaved) where possible also include Pro Tools session folder. Where non Pro Tools sessions are delivered all channel must be rendered to continuous PCM audio.

  • Lossy or lossless audio compression is never allowed. Audio must be linear PCM

  • Sample Rate and Bit Depth:

  • 48k/24bit for Original Mix, Stems & Mix Masters.

48k/16bit are allowed only for alternate version of Alternate Master Version (CD, Digital, Radio edit, Promo, Teaser, .. )

1.1 Audio Master LR - Original Version and Alternate Version

  • Use 79 db SPL as your standard reference level for mixing.

  • Meet a 21 LKFS (+/- 4 LU) average music level using ITU-R BS.1770-1 measured over entire track.

  • Mantain +16 db (-6 dbfs) maximum level (true peak) over reference of -20 dbfs, achieved over peak limiting and not lowering mix level.

  • Provide LR Vocal, Percussive, Bass, Synth, Strings stems that equal the 2.0 mix when combined with the Original Version.

  • Lo/Ro mix are preferred and mono compatible

1.2 Audio Stems LR - Original Version

  • 48kHz/24 bit minimum.

  • Provide a separate fully filled 2.0 stereo mix containing only instruments (no vocals).

  • Provide (when applicable), for each Stem, a separate 2.0 stereo mix that include all reverbs, delays and other effects that correctly matches that instrument in the original mix.

  • Otherwise provide Stems in “clean version”(see Stems Creation Guidelines) including a separate 2.0 stem-track with all the DPS returns that correctly matches original mix.

  • For mixers creating the Stems please reference Stems Creation Guidelines.

  • All levels should mirror what used for final Mastering and Archive so that any newly submix can be delivered in easily later.

1.2 Audio Stems LR - Original Version

  • 48kHz/24 bit minimum.

  • Provide a separate fully filled 2.0 stereo mix containing only instruments (no vocals).

  • Provide (when applicable), for each Stem, a separate 2.0 stereo mix that include all reverbs, delays and other effects that correctly matches that instrument in the original mix.

  • Otherwise provide Stems in “clean version”(see Stems Creation Guidelines) including a separate 2.0 stem-track with all the DPS returns that correctly matches original mix.

  • For mixers creating the Stems please reference Stems Creation Guidelines.

  • All levels should mirror what used for final Mastering and Archive so that any newly submix can be delivered in easily later.

2.0 Audio Mix, Stems and Archive

For Archive:

 

  • All deliverables should be conformed and synced to the 2.0 stereo audio master of Original Version.

  • Alternate Version such as Radio Edit, Promo, Teaser must respect guidelines of the Original Version and delivered separately from Original Mix & Stems folder. 

———————————————————————————————————————

2.0 Audio Mix, Stems and Archive

For Archive:

 

  • All deliverables should be conformed and synced to the 2.0 stereo audio master of Original Version.

  • Alternate Version such as Radio Edit, Promo, Teaser must respect guidelines of the Original Version and delivered separately from Original Mix & Stems folder. 

———————————————————————————————————————

3.0 Best Practices

Note: The following are not Technical Specifications. They are guidelines designed to help achieve an optimal production library’ customer experience. Following these guidelines is not required by BNC Music. BNC Music is committed to protecting creative intent - we do not compress, limit or modify audio mixes.

For best results, measure music levels between -17 LKFS to -25 LKFS with -21 LKFS as a target. We suggest WLM Meter stereo, or NuGEN Vis-LM, which should be set to ITU-R BS.1770-1 ———————————————————————————————————————

For any questions or further info please contact us by sending a mail to : lyramusicfortales@gmail.com